A. Installation of system shall be in strict accordance with approved shop drawings and manufacturer's printed and video instructions.
1. If used to conceal fire sprinkler systems, the sprinkler contractor/engineer must determine the piping and sprinkler layout, including sprinkler head locations and pipe support locations (based on pipe manufacturer's specs.). Indicate areas on drawings where cover system is to be used.
2. Select appropriate fasteners for the substrate encountered to adequately secure the pipe and cover system.
3. To insure that the cover is linear and snug-fitting when installed, it is imperative that its support devices are anchored squarely and firmly in a straight line against the structural surface.
4. All penetrations to the soffit/cover system shall be field cut to prevent misalignment with intended protrusion. The exceptions to this are that access doors may be factory furnished and installed and perforations, if required, may be factory perforated.
5. Guidelines for installation of modular soffit/cover system shall be supplied by the manufacturer of said system and the installing contractor shall adhere to the manufacturer's guidelines. Such guidelines shall be supplied by manufacturer in the form of both written and video installation instructions.
6. Manufacturer shall, upon installer's request, supply on-site installation instruction by a qualified installation instructor for a minimum of one day for the project start-up (1,500 lineal feet minimum.)
7. The completed installation shall be visibly searched for voids between the interfacing of the cover and construction surface. Voids shall be sealed with the following security sealant: Ultra Polyurethane Sealant